Description
Pouch Press Tester / Static Load Tester
Pouch Press Tester is suitable for Static Load Test on Liquid Filled pouches.
Test Type : Press till Load Setpoint. Hold till Time Setpoint.
In this method, the sample is compressed upto a preset Load. The applied force is held on the pouch for preset time. After the times elapses, the machine returns to the original position.
Technical Specifications :
Touchscreen Model
Automatic Operation |
Analog (Economy) Model
Manual Operation No Power Supply Required |
Digital Model with Touchscreen Display (PLC). | Analog Model with Dial Type Pressure Gauge. |
Touch controls on PLC. | Manual Up / Down Lever. |
Set Load (machine calculates pressure). | Set Pressure (calculate load manually). |
Auto-adjust pressure. No Manual Control. | Manual Pressure Setting via Pressure Regulator. |
Safety Shield with Interlock. | Safety Shield without Interlock. |
Test Procedure
|
Test Procedure
|
Choice of Measurement units (Menu Selection)
Kgf / Lbf / N |
Only ‘bar’ unit.
“Force” conversion, formula will be provided. |
Stainless Steel Body | Mild Steel Body with Paint |
Safety Features of Touchscreen Model :
- The front door will have a magnetic latch or microswitch.
- Sample can be placed or removed by opening the front safety door.
- If the door is not closed completely, the machine will NOT START.
- If someone opens the door in the middle of the test sequence, the machine will stop and reverse automatically.
Included with all models / SKUs :
- Safety Door with or without interlock
- Air Filter + Pressure Regulator.
DQ/IQ/OQ Documentation are supplied with models specific for Pharmaceutical Companies.
Warranty : 12 Months (Ex-Factory)
Note : The Static Load Test is done as per test specifications detailed in point # 4.1.2 of Chapter 4 of the “Flexible Retort Pouch Defects – Identification & Classification” by the Canadian Food Inspection Agency.
As per Canadian Food Inspection agency, retort pouches should comply with the static load burst test. You will have to press the pouch with a force of 7.5 kg per 15mm of inner seal perimeter and hold this force for 15 seconds. If the pouch leaks or bursts or even if the seals show signs of stress during this period, the batch is considered failed. |
Utilities Required for Touchscreen Model :
- Power Supply (Current : Max 5 Amps) :
- For India (Domestic Model) : 230 Volts A.C., 50 Hz. Clean power.
- For Outside India (Export Model) : As per your country’s power rating.
- Compressed Air @ 6 bar (87 psi)
Utilities Required for Analog Model :
- Compressed Air @ 6 bar (87 psi)
Capacity Options :
500 | 1000 | |
Capacity : | 500 Kgf / 4900 N / 1100 Lbf | 1000 Kgf / 9800 N / 2200 Lbf |
Size Options :
Platform Size | Pressing Platen Diameter | Max Pouch Size (Diagonal Distance) |
S – Small | 200 mm (~ 8 inch) | 200 mm (~ 8 inch) |
M – Medium | 300 mm (~ 12 inch) | 300 mm (~ 12 inch) |
L – Large | 400 mm (~ 16 inch) | 400 mm (~ 16 inch) |